RM 1902, EASEY GBD., 253-261 HENNESSY STRASSE, WANCHAI, HONG KONG | jason@hydraulicpumpvalve.com |
Herkunftsort: | USA |
Markenname: | Eaton Vickers |
Modellnummer: | PVXS-066M02R0001A01SV0ADF000A0F00000000000000010 PVXS-090M02R0001R01SVVADF000A0000000000000000010 PV |
Min Bestellmenge: | 1 |
---|---|
Preis: | On request |
Verpackung Informationen: | Papier- oder hölzerner Karton |
Lieferzeit: | 7-10days |
Zahlungsbedingungen: | T / T, Western Union |
Versorgungsmaterial-Fähigkeit: | 100/month |
Modell Nr.: | PVWS-250M07R0001R01SVVALR000A201100100H000000010 | Modell: | PVXS-250M06R0001R01SCVADF000A000000100H000000010 |
---|---|---|---|
Typ: | PVXS-180M04R0001R01SVVADF000A0F00000000000000010 | Material: | PVXS-066M02R0001A01SV0ADF000A0000000000028700010 |
Hervorheben: | eaton vickers Kolbenpumpen,hydraulische Axialkolbenpumpe |
Reihen-offene Schleife-Kolbenpumpen Eaton Vickers PVXS
Pumpen-Maße
PVXS 066 - 250 DF, zweistufiges Regelventil
PVXS 066 - 250 DF, wenn die Last Ventil abfragt
PVXS 066 - 250 LR, mit Druck-Begrenzer
PVXS 066 - 250 ES
PVXS 066 - DP 250, mit Stütze. Regelventil
PVXS 066 - SP 250, mit Stütze. Regelventil
Durch - Antriebe
Keilwelle
SAE4 - Bolzen-Montage, Installations-Daten
Offene Schleife-Kolbenpumpe Eaton Vickers Hydrokraft
Verschiebung: 66 cm (4,0 in3) – 250 cm (15/2 in3).
Bewerteter Druck: Stange 350 (5.000 P/in)
Die Kolbenpumpe Vickers Hydrokraft PVXS ist die Hochdruck (Axialkolbenpumpen der Stange 350), die für industrielle Märkte bestimmt sind. Die PVXS-Pumpen sind weit verbreitet, wo ihre Strecke der fachkundigen Pumpenkontrollen Stromkreise optimieren kann. Anwendungen: Asphaltieren Sie die Umformung, das verbiegende Rohr, Pressung, Marinesoldaten und Offshorehandkurbeln, mischendes Reiben der Chemikalie/Zerreißen und hydraulische Stromversorgung.
– Axialkolbenpumpen mit Taumelscheibe entwerfen für zuverlässige Operation und langes Leben.
– Überformatwellen und Lager.
– Drehende und Druck geladene Teile sind der balancierte Druck.
– Integrierte Versuchspumpe, Filter und Druckablassventile verfügbar.
– „Baustein“ Entwurf gibt diesen Pumpen eine breite Palette der Anwendung.
Technische Daten
Tabelle von Werten (Sollwerte, ohne Leistungsfähigkeit und Toleranzen; Werte gerundet)
Vickers-Pumpe PVXS | 66 | 90 | 130 | 180 | 250 | ||
Rohrverbindung SAE/Flange | B | P/in | 1 1/2 ″ = 3000 | ″ 2 = 3000 | 2 1/2 ″ = 3000 | 2 1/2 ″ = 3000 | 3 1/2 ″ = 500 |
A | 1 ″ = 6000 | 1 ″ = 6000 | 1 ″ = 6000 | 1 1/4 ″ = 6000 | 1 1/4 ″ = 6000 | ||
Drehsinn | Nach rechts wenn Wellenende der Pumpe angesehen wird | ||||||
Nach linksverfügbares auf Anfrage | |||||||
Drehzahlbereich | nmin | min-1 | 150 | ||||
nmax | 1800 | ||||||
Maximales geometrisches n= 1500 Verschiebung min-1 n= 1800 min-1 | Verstell- | cm3 | 66 | 90 | 130 | 180 | 250 |
Maximales geom. n= 1500 min-1
Pumpenfluß n= 1800 min-1 |
Qg | L/min | 99 | 135 | 195 | 270 | 375 |
118 | 162 | 234 | 324 | 450 | |||
Masse der Trägheit | J | Kilogramm m2 | 0,016 | 0,016 | 0,045 | 0,045 | 0,146 |
Gewicht | m | Kilogramm | 55 | 75 | 106 | 114 | 212 |
Verschiebungskontrollen:
ES – ElektromotorVerschiebungskontrolle
Hektogramm – Handrad-Verschiebungskontrolle
F.E. – Schraubenanpassungssteuerung (spezielle Eigenschaft)
DF – Druckkompensator gesteuert
DQ – Liegeplatzsteuerung
LR – Sendeleistung mit Druckbegrenzer
SP, Inspektion – Verschiebung proportional zum elektrischen Signal
DP – Verschiebung proportional zum Drucksignal
HC806052039501 | PVXS-066M02R0001A01SV0ADF000A0F00000000000000010 |
HC806052040000 | PVXS-066M02R0001A01SV0ADF000A0000000000000000010 |
HC806052041700 | PVXS-066M02R0001R01SV0ADF000A0000000000000000010 |
HC806052041701 | PVXS-066M02R0001R01SVVADF000A0000000000000000010 |
HC806052042302 | PVXS-066M02R0001A01SVVADF000A0000000000000000010 |
HC806052042309 | PVXS-066M02R0001A01SVVADF000A0F00000000000000010 |
HC806052042316 | PVXS-066M02R0001R01SV0ADF000A0F00000000000000010 |
HC806052042322 | PVXS-066M02R0001R01SVVADF000A0F00000000000000010 |
HC806052042333 | PVXS-066M02R0001A01SV00DF000A0000000000020800010 |
HC806052042336 | PVXS-066M02R0001A01SV0ADF000A0000000000028700010 |
HC806052051804 | PVXS-090M02R0001R01SVVADF000A0000000000000000010 |
HC806052051806 | PVXS-090M02R0001R01SV0ADF000A0000000000000000010 |
HC806052051808 | PVXS-090M02R0001R01SV0ADF000A0F00000000000000010 |
HC806062041400 | PVXS-130M04R0001A01SV0ADF000A0000000000000000010 |
HC806062042002 | PVXS-130M04R0001R01SVVADF000A0000000000000000010 |
HC806062042003 | PVXS-130M04R0001R01SV0ADF000A0000000000000000010 |
HC806062042011 | PVXS-130M04R0001R01SVVADF000A0000000000024200010 |
HC806062042110 | PVXS-130M04R0001R01SVVADF000A0F00000000000000010 |
HC806062043703 | PVXS-130M04R0001R01SV0ALR000A2F03000000000000010 |
HC806062052119 | PVXS-180M04R0001R01SV0ALR000A2F03700000000000010 |
HC806062058000 | PVXS-180M04R0001R01SV0ADF000A0000000000000000010 |
HC806062058002 | PVXS-180M04R0001R01SVVADF000A0000000000000000010 |
HC806062058005 | PVXS-180M04R0001R01SV0ADF000A0F00000000000000010 |
HC806062058019 | PVXS-180M04R0001R01SVVADF000A0F00000000000000010 |
HC806062058042 | PVXS-180M04R0001R01SVVADF000A0F00000000025200010 |
HC806062059005 | PVXS-180M04R0001R01SV0ALR000A2008300000000000010 |
HC806062059007 | PVXS-180M04R0001R01SV0ALR000A2002900000000000010 |
HC806062059010 | PVXS-180M04R0001R01SVVALR000A2005500000000000010 |
HC806072033600 | PVXS-250M06R0001A01SV0ADF000A0F00000000000000010 |
HC806072036500 | PVXS-250M06R0001R01SV00DF000A0000000000002200010 |
HC806072036502 | PVXS-250M06R0001R01SV0ADF000A0000000000000000010 |
HC806072036503 | PVXS-250M06R0001R01SVVADF000A0000000000000000010 |
HC806072036509 | PVXS-250M06R0001R01SV0ADF000A0F00000000000000010 |
HC806072036514 | PVXS-250M06R0001R01SVVADF000A0F00000000000000010 |
HC806072038626 | PVXS-250M06R0001R01SV0ALR000A2018000000000000010 |
HC806072038700 | PVXS-250M06R0001A01SV0ADF000A0000000000000000010 |
HC806072038709 | PVXS-250M06R0001A01SVVADF000A0F00000000000000010 |
HC806072038900 | PVXS-250M06R0001A01SVVADF000A0000000000000000010 |
HC806072040000 | PVXS-250M06R0001A01SV0ADF000A000000100H000000010 |
HC806072041100 | PVXS-250M06R0001R01SVVADF000A000000100H000000010 |
HC806072041300 | PVXS-250M06R0001R01SC0ADF000A0000000000000000010 |
HC806072041301 | PVXS-250M06R0001R01SCVADF000A0000000000000000010 |
HC806072041302 | PVXS-250M06R0001R01SCVADF000A0F00000000000000010 |
HC806072041305 | PVXS-250M06R0001R01SCVADF000A000000100H000000010 |
Ansprechpartner: Mr. Jason
Hydraulikpumpe Reihe A10VSO18 Rexroth, variable Axialkolbenpumpe
Variable Hochdruckreihe der hydraulikpumpe-A10VSO45 mit langer Nutzungsdauer
Hydraulikpumpe schnelle Geschwindigkeit Rexroth, variabler Kolben-Hydraulikpumpe der Reihen-A10VSO71
Reihe ISO des Hydac-Druckfilter-Element-Ersatz-0240D 0260D 0280D genehmigte
Drücken Sie Reihe Ersatz-Filterelement Hydac 0800D 0900D 1320D 1500D
Reihen-Rückleitung Elemente Hydac 0240R für hydraulischen Rückholnetzfilter
Parker Denison hydraulische Reihe des Kolbenpumpe-variable Volumen-PVP16
Hydraulikpumpe-variable Volumen-Kolbenpumpen Reihe PVP41 Parker Denison
Hydraulikpumpe-Axialkolbenpumpe Parker Reihe PV140 PV180 an Hand